1. Using the template provided with anti-tip kit, locate the preferred
location for installation of the anti-tip bracket and mark the location of
the screw holes. Bracket may be installed at either the back-left or back-
right corner of the installation space.
NOTE:
• Only one anti-tip bracket needs installed.
2. Follow the instructions specific to your construction.
Wood Construction
• Drill a 1/8" pilot hole where screws are to be located. If bracket is to
be mounted to the wall, drill pilot hole at an approximate 20°
downward angle. Screw must enter wood.
Masonry Construction
• Due to the variety of masonry materials that may be present at
installation site, hardware is not provided for attaching the anti-tip
bracket to masonry. If bracket is to be mounted to masonry or
ceramic floors, attach anti-tip bracket using two 5/16" OD sleeve
anchors (with 1/4" bolt - either hex bolt head or hex nut head) rated
for minimum 300lb tension for the masonry material present at
installation site. Screw must enter masonry.
3. Secure anti-tip bracket to floor or wall with the screws provided.
More than 1-1/4"
Anti-tip bracket
Leveling leg
Mounting screw (floor)
Wall
Installation with
rear left leg
Installation with
rear right leg
or