Installation Guide

INSTALLATION GUIDE
REGULATION OF BURNER FLAME INTENSITY
To regulate the minimum flame on the burners, carry out the
following procedure indicated below:
1) Turn on the burner and put the knob onto position MINIMUM
( small flame ).
2) Remove the knob ( Fig. 9) of the tap which is set for standard
pressure. The knob is found on the shaft of the valve itself.
3) Beside the valve shaft, use a small screwdriver that fits the
gold colored screw found on the lower part of the tap (auxiliary,
semirapid, rapid Fig. 9) (dual fig.10) and turn the adjustment
clock-wise or counter clock-wise until the minimum flame
reaches a desired intensity level.
4) Make sure that that the flame does not go out when changing
the position quickly from MAXIMUM to the MINIMUM position. If
it does, the minimum flame intensity needs to be increased.
11