Use and Care Guide
WARNING! 
BEFORE INSTALLATION
This appliance shall only be installed by an 
authorized professional. 
This appliance shall be installed in accordance 
with the manufacturer's installation instructions. 
This appliance must be installed in accordance 
with the standards of the country where it will 
be installed. The installation of this appliance 
must conform to local codes and ordinances. In 
the absence of local codes, Installations must 
conforms to American National Standards, 
National Fuel Gas Code ANSI Z223.1 - latest 
edition/NFPA 54 or B 149.1. 
The appliance, when installed, must be 
electrically grounded in accordance with local 
codes or, in the absence of local codes, with the 
National Electrical Code, ANSI/NFPA 70. 
If local codes permit, a flexible metal appliance 
connection with the new AGA or CGA certified 
design, max. 5 feet (1,5 m) long, 3/4" I.D. is 
recommended for connecting this appliance to 
the gas supply line. Do not bend or damage the 
flexible connector when moving the appliance. 
This appliance must be used with the pressure 
regulator provided. The regulator shall be 
properly installed in order to be accessible when 
the appliance is installed in its final location. The 
pressure regulator must be set for the type of 
gas to be used. The pressure regulator has 3/4" 
female pipe thread. The appropriate fitting must 
be determined based on the size of your gas 
supply line, the flexible metal connector and the 
shutoff valve. 
The appliance must be isolated from the gas 
supply piping system by closing its individual 
manual shutoff valve during any pressure 
testing of the gas supply piping system at test 
pressures equal to or less than 34 PSI (13,8 w.c. 
pr 3,5 kPa). 
All opening and holes in the wall and floor, back 
and under the appliance shall be sealed before 
installation of the appliance. 
A manual valve shall be installed in an 
accessible location in the gas line external to 
the appliance for the purpose of turning on or 
shutting off gas to the appliance 
Do not use aerosol sprays in the vicinity of 
this appliance while it is in operation 
ROOM VENTILATION: An exhaust fan may be 
used with the appliance; in each case it shall be 
installed in conformity with the appropriate 
national and local standards. Exhaust hood 
operation may affect other vented appliances; in 
each case it shall be installed in conformity with 
the appropriate national and local standards. 
   
This appliance is shipped from the factory for 
use with natural gas. Propane Conversion Kit 
must be purchased separately. For use with 
propane LP gas please follow the conversion 
procedure described on pg. 17. 
  
The maximum inlet gas supply pressure 
incoming to the gas appliance pressure 
regulator is 34 PSI (13,8 w.c. pr 3,5 kPa). 
The minimum gas supply pressure for checking 
the regulator setting shall be at least 1" w.c. (249 
Pa) above the inlet specified manifold pressure 
to the appliance (this operating pressure is 4" 
w.c. (1.00 kPa) for Natural Gas and 11" w.c. (2.75 
kPa for LP Gas).