Use and Care Guide
DO  NOT  USE  EXTENSION CORDS WITH 
THIS  APPLIANCE  AS  IT  MAY  RESULT  IN 
FIRE,  ELECTRIC  SHOCK  OR  OTHER 
type  of  PERSONAL INJURY. 
The appliance is equipped at the factory with an
electric supply cord set 4 wires type with ring 
terminals (L1, L2, N, Ground) suitabl e for range
use UL/CSA listed type SRDT/DRT 2x6AWG (L1, 
L2)+2x8AWG (N, G) rated 300V, 40 or 50A with
fused plug type NEMA 14‐50P; cable length 1,5 
m.;incasethesupplycordsetmustbereplaced,it 
shall be replaced with anidentical set having the 
same technical specs  and following carefully the
instructionsanddiagramsbelow:
1) Disconnect appliance f rom electrical power
supplyreceptacle
2) Slideouttheappliancefrominstallationplace
toaccesstobackenclosurepanel
3) Remove back enclosure panel  by removing
the6screwsasshownbelow
4)
Loosestrainreliefbyunscrewingthetwo
strainrelief'sscrewsasindiagram.
5)
Remove damaged supply cord set by taking 
off the 4 electrical connection screws (block L1,
N,L2andGroundscrew,seediagram)
6) Insert the new supply cord set in the strain
relief and  lock it  with two  strain  relief's
screwsinsuitableposition.
7) FixwelltheringterminalsG,L1,N,L2ofthe
new  supply  cord  set  asshown  in  diagram
withits4screws
8) Re‐install  the back enclosure  panel  with  6
screws
9) Slide  the  appliance  back  into  itsproper
location
10) Re‐connect  the  appliance  to  the  electrical
power.
12
POWER CORD REPLACEMENT