Manual and User Guide
Manifold pressure should be checked with a 
manometer and comply with the values indicated 
below: 
Natural gas -> 4.0" W.c.P. 
LP/Propane -> 10.0" W.C.P. 
Incoming line  pressure upstream from the 
regulator must be 1" W.c.P. higher than the 
manifold pressure in order to check the regulator. 
The regulator used on this range can withstand a 
maximum input pressure of 1/2 PSI (13.8" w.c. or 
3,5 kPa) If the line pressure exceeds that amount, 
a step-down regulator is required. 
The appliance, its individual shut-off valve, and 
the pressure regulator must be disconnected from 
the gas line during any pressure testing of that 
system at pressures in excess of 1/2 PSI (13.8" 
w.c. or 3,5 kPa). 
The individual manual shut-off valve must be in the 
OFF position during any pressure testing of the 
gas supply piping system at test pressures equal 
to or less than 1/2 PSI (13.8" w.c. or 3,5 kPa). 
  
Before carrying any service disconnect 
the appliance from gas appliance from final install 
have access to the appliance for proper servicing 
intervention. 
PRESSURE REGULATOR 
Since service pressure may fluctuate with 
local demand, every gas cooking appliance 
must be equipped with a pressure regulator 
on the incoming service line for safe and 
efficient operation. 
The pressure regulator shipped with the 
appliance has two female threads 34" NPT. 
The regulator shall be installed properly in 
order to be accessible when the appliance 
is installed in its final position. 
GAS CONVERSION 
WARNING! 
Before carrying out this operation, 
disconnect the appliance from gas 
and electricity. 
Gas conversion shall be conducted by a 
factory- trained professional. 
Call the customer service hotline to identify a 
factory-trained professional near your home. 
The gas conversion procedure for this range 
includes 6 steps: 
1. Pressure regulator
2. Surface burners
3. Adjustment of minimum setting
The conversion is not completed if all 6 steps 
have not been concluded properly. 
Before performing the gas conversion, locate 
the package containing the replacement nozzle 
shipped with every range. IMPORTANT: Each 
nozzle has a number indicating its flow 
diameter printed on the body. Consult the table 
on page 20 for matching nozzles to burners. 
Save the nozzles removed from the range for 
future use.
1