Manual and User Guide
GAS CONNECTION 
    
To avoid gas leaks, the pressure test-point stopper 
valve and gasket supplied with the range must be 
installed on the gas fitting at the back of the range 
according to the diagram below. 
M  
All gas connections must comply with national 
and local codes. The gas supply line (service) 
must be the same size or greater than the inlet 
line of the appliance. This range uses a 1/2" 
NPT inlet (see drawing below for details of gas 
connection). On all pipe joints use appropriate 
sealant resistant to gas. 
This range can be used with Natural or 
LP/Propane gas. The range is shipped from the 
factory for use with natural gas. 
For LP/propane household installation, the 
appliance must be converted by the dealer, by a 
factory-trained professional or by a qualified 
licensed plumber or gas service company. 
Gas conversion is important for safe and 
effective use of the appliance. It is the 
responsibility of the dealer and the owner of the 
range to perform the appropriate gas 
conversion following the directions of the 
manufacturer. 
THE GAS CONVERSION PROCEDURE IS 
DESCRIBED IN THIS MANUAL AND IN 
THE PACKAGE CONTAINING THE 
CONVERSION NOZZLES SHIPPED WITH 
EVERY RANGE. 
Please provide the service person with this 
manual before work is started on the range. 
WARNING! 
DO NOT USE AN OPEN FLAME WHEN 
CHECKING FOR LEAKS!
THIS VALVE IS NOT SHIPPED WITH 
THE APPLIANCE AND MUST BE 
SUPPLIED BY THE INSTALLER.
The manual shut-off valve must be installed 
in the gas service line between the gas 
hook-up on the wall and the appliance inlet, 
in a position where it can be reached quickly 
in the event of an emergency. 
In Massachusetts: A T handle type manual 
gas valve must be installed in the gas 
supply line to this appliance. 
  
In case of installation with flexible couplings 
and/or quick-disconnect fittings, the installer 
must use a heavy-duty, AGA 
design-certified commercial flexible 
connector of at least 1/2" (1.3 cm) ID NPT 
(with suitable strain reliefs) in compliance 
with ANSI Z21.41 and Z21.69 standards. 
In Massachusetts: The unit must be 
installed with a 36" (3-foot) long flexible gas 
connector. 
In Canada: use CAN 1-6.10-88 metal 
connectors for gas appliances and CAN 
1-6.9 M79 quick disconnect device for use 
with gas fuel.
Leak testing of the appliance shall be 
conducted according to the manufacturer's 
instructions. Before placing the oven into 
operation, always check for leaks with soapy 
water solution or other acceptable method. 
Check for gas leakage with soapy water 
solution or other acceptable methods in all gas 
connections installed between inlet gas pipe of 
the appliance, gas regulator, till to the manual 
shut-off valve.
1










