Installation Guide
INSTALLATION SAFETY & WARNINGS
5
WARNING!  Do  not  use  aerosol  sprays  in 
the vicinity  of  this  appliance  while 
it  is  in operation.
ROOM VENTILATION
An exhaust fan may be used with the appliance;
in  each  case  it  shall  be  installed  in  conformity
with the appropriate national and local standards.
Exhaust hood operation may affect other vented
appliances;  in  each  case  it  shall  be  installed  in
conformity with the appropriate national and local
standards.
TYPE OF GAS
This appliance is shipped from the factory for use
with  natural  gas.  Propane  Conversion  Kit  must
be  purchased  separately.  For  use  with  propane
LP  gas  please  follow  the  conversion  procedure
described on pg. 17.
GAS PRESSURE
The  maximum  inlet  gas  supply  pressure
incoming to the gas appliance pressure regulator
is 34 PSI (13,8 w.c. pr 3,5 kPa).
The  minimum  gas  supply  pressure  for  checking
the regulator setting shall be at least 1" w.c. (249
Pa)  above  the  inlet  specified  manifold  pressure
to  the  appliance  (this  operating  pressure  is  4"
w.c.  (1.00  kPa)  for  Natural  Gas  and  11"  w.c.
(2.75 kPa for LP Gas).
This appliance shall only be installed by an
authorized professional.
This  appliance  shall  be  installed  in
accordance  with  the  manufacturer's
installation instructions.
This appliance must be installed in accordance
with  the  standards  of  the  country  where  it  will
be  installed.  The  installation  of  this  appliance
must conform to local codes and ordinances. In
the  absence  of  local  codes,  Installations  must
conforms  to  American  National  Standards,
National  Fuel  Gas  Code  ANSI  Z223.1  -  latest
edition/NFPA 54 or B 149.1.
The  appliance,  when  installed,  must  be
electrically  grounded  in  accordance  with  local
codes  or,  in  the  absence  of  local  codes,  with
the National Electrical Code, ANSI/NFPA 70.
If local codes permit, a flexible metal appliance
connection with the new AGA or CGA certified
design,  max.  5  feet  (1,5  m)  long,  3/4"  I.D.  is
recommended  for  connecting  this  appliance  to
the gas supply line. Do not bend or damage the
flexible connector when moving the appliance.
This appliance must be used with the pressure
regulator  provided.  The  regulator  shall  be
properly  installed  in  order  to  be  accessible
when  the  appliance  is  installed  in  its  final
location. The pressure regulator must be set for
the  type  of  gas  to  be  used.  The  pressure
regulator  has  3/4"  female  pipe  thread.  The
appropriate  fitting  must  be  determined  based
on the size of your gas supply line, the flexible
metal connector and the shutoff valve.
The  appliance  must  be  isolated  from  the  gas
supply  piping  system  by  closing  its  individual
manual  shutoff  valve  during  any  pressure
testing  of  the  gas  supply  piping  system  at  test
pressures  equal  to  or  less  than  34  PSI  (13,8
w.c. pr 3,5 kPa).
All opening and holes in the wall and floor, back
and under the appliance shall be sealed before
installation of the appliance.
A  manual  valve  shall  be  installed  in  an
accessible  location  in  the  gas  line  external  to
the  appliance  for  the  purpose  of  turning  on  or
shutting off gas to the appliance