Installation Guide
11
POWER CORD REPLACEMENT
DO  NOT  USE  EXTENSION
CORDS WITH THIS APPLIANCE
AS  IT  MAY  RESULT  IN  FIRE,
ELECTRIC  SHOCK  OR  OTHER
TYPE OF PERSONAL INJURY.
The    appliance    is    equipped    at
the    factory    with  an  electric
supply    cord    set    4    wires    type
with  ring  terminals    (L1,    L2,    N,
Ground)    suitable    for  range  use
UL/CSA    listed    type  SRDT/DRT
2x6AWG   (L1,  L2)+2x8AWG    (N,
G)    rated    300V,  40  or  50A  with
fused  plug  type  NEMA  14-50P;
cable  length  1.5m  in  case  the
supply cord set must be replaced,
it  must  be  replaced  with  an
identical  set  having  the  save
technical  specifications  and
installed  using  the  following
directions:
1.)  Disconnect  appliance  from
electrical power supply receptacle
2.)  Slide  out  the  appliance  from
the  installation  place  to  access
the back enclosure
3.) Remove back enclosure panel
by  removing  the  6  screws  as
shown below.
4.)  Loose  strain  relief
by  unscrewing  two
strain  relief's  screws  in
diagram
5.)  Remove  damaged
supply cord set by taking off
the  4  electrical  connection
screws (block L1, N, L2 and
Ground  screw,  see
diagram)
6.)  Insert  the  new  supply
cord  set  in  the  strain  relief
and  lock  it  with  two  strain
relief’s  screws  in  suitable
position
7.)  Fix  well  the  ring
terminals  G,  L1,  N,  L2  of
the new supply cord set, as
shown in diagram with its 4
screws
8.)  Reinstall  the  back
enclosure  panel  with  6
screws
9.) Slide the appliance back
into its proper location
10.)  Reconnect  the
appliance  to  the  electrical
power