Rating Label
The  appliance  shall  be  connected  to  a  single
phase electric line rated at 120 208Vac or 120/
240Vac and 60Hz frequency.
ELECTRIC POWER RATING
• 120/208Vac: 10 A max
• 120/240Vac: 12 A max
HEATING ELEMENTS POWER RATING
• Oven bake element = 1500 Watt
• Oven circular element = 3200 Watt
• Oven broil element = 2850 Watt
Install  a  suitable  electric  power  supply
receptacle connection type NEMA 14-50R able
to  support  a  load  of  at  least  30  A  (per  line)
according to local code requirements. For four
wires  power  supply  connection  system  see
diagram below.
Check your local code for which of the options
below  should  be  used  in  grounding  the
receptacle power suppliy connections.
FOUR WIRES CONNECTION
•  Connect  the  L1  receptacle  terminal  to  the
incoming  BLACK  electrical  supply  wire(L1-hot
wire)
•  Connect  the  L2  receptacle  terminal  to  the
incoming  RED  electrical  supply  wire  (L2-hot
wire)
• Connect the NEUTRAL receptacle terminal to
the  incoming  NEUTRAL  (WHITE)  electrical
supply wire
• Connect the GROUND receptacle terminal to
the  incoming  GROUND  (GREEN)  electrical
supply wire
ELECTRICAL GROUNDING
This  appliance  is  equipped  with  a  four-
prong  plug  for  your  protection  against
shock  hazard  and  should  be  plugged
directly  into  a  properly  grounded
receptacle,  do  not  cut  or  remove  the
prong from this plug.
WARNING
ELECTRICAL SHOCK HAZARD
Disconnect  electrical  power  at  the
circuit breaker box or fuse box before
installing  the  appliance.  Provide
appropriate  ground  for  the  appliance.
Use copper conductors only. Failure to
follow these instructions could result
in serious injury or death.
DO  NOT  USE  EXTENSION  CORDS
WITH  THIS  APPLIANCE  AS  IT  MAY
RESULT  IN  FIRE,  ELECTRIC  SHOCK
OR  OTHER  TYPE  OF  PERSONAL
INJURY.
Label  all  wires  prior  to  disconnecting
when  servicing  controls.  Wiring  errors
can  cause  improper  and  dangerous
operation.  Verify  proper  operation  after
servicing.
When  working  with  electrical
connection,  please  refer  to  the  rating
label, the rating label is located near the
entrance of power supply cord.
ELECTRICAL CONNECTION