LP/PROPANE GAS CONVERSION 
IMPORTANT: Gas conversions must be done by a qualified service technician 
in accordance with the manufacturer's instructions and all codes and 
requirements of the authority having jurisdiction. The qualified agency 
performing this work assumes the gas conversion responsibility. 
Convert Gas Pressure Regulator 
Regulator Cap
Retainer Pin
Natural gas 
position
Propane gas 
position
1. Turn manual shutoff valve to the closed position.
2. Unplug range or disconnect power.
3. Locate the gas pressure regulator on the back of the range.
IMPORTANT: Do not remove the gas pressure regulator.
4. Unscrew the regulator cap with the wrench.
5. Remove the retainer pin that is currently positioned for use with natural
gas.
6. Turn the retainer pin upside down and place it back into the regular cap.
The regular cap is now positioned for use with LP gas.