Installation Guide
24 
This appliance shall be installed only by authorized persons and in 
accordance with the manufacturer's installation instructions, local gas fitting 
regulations, municipal building codes, electrical wiring regulations, local 
water supply regulations. 
This range is factory-set for use with Natural gas. To use this range with 
Propane gas, see the "GAS CONVERSION section before connecting this range 
to the gas supply. Gas conversions from Natural gas to Propane gas or from 
Propane gas to Natural gas must be done by a qualified installer. 
TYPICAL FLEXIBLE CONNECTION 
b
c
e
a
d
d
Adapter (provided)
Gas Pressure Regulator
Gas Supply Line
Adapters (From Gas 
Supply Line Kit)
Gas Shutoff Valve
b
a
c
d
e
1. Apply pipe-joint compound made for use with LP gas to the smaller
thread ends of the flexible connector adapters.
2. Attach one adapter to the gas pressure regulator and the other adapter
to the gas shutoff valve. Tighten both adapters, being certain not to
move or turn the gas pressure regulator.
3. Use a 15/16" (2.4 cm) combination wrench and channel lock pliers to
attach the flexible connector to the adapters. Check that connector is not
kinked.