Use and Care Manual

28 29
INSTALLATION INSTRUCTIONS
LP/Propane Gas Conversion
This appliance can be used with Natural Gas or LP/Propane gas. It is shipped from the factory for
use with natural gas. A kit for converting to LP gas is supplied with your cooktop. The kit is marked
"FOR LP/PROPANE GAS CONVERSION".
When the cooktop is converted for liquid pretroleum (LP) gas, the LP gas supply is required to
provide a minimum of 10” to a maximum of 14” water column to the cooktop regulator.
The conversion must be performed by a qualified service technician in accordance with
the kit instructions and all local codes and requirements. Failure to follow instructions could
result in serious injury or property damage. The qualified agency performing this work
assumes responsibility for the conversion.
BURNER TYPE
MAX
MIN
Natural Gas
LPG
OUTPUT
OUTPUT
Kw
Kw
Nozzle
Cons
Nozzle
Cons
mm
M
3
/h
mm
g/h
Auxiliary Burner
1
0.3
1 x 1.10
0.1
1 x 0.70
73
Semi-Rapid Burners
2
0.55
1 x 1.20
0.19
1 x 0.80
124
Triple Ring Burner
4.5
1.5
5 x Φ0.99
0.43
5 x Φ0.56
327
Figure 18
WARNING
Failure to make the appropriate conversion can result in serious personal injury and property
damage.
TOOLS YOU WILL NEED FOR CONVERSION
Wrench
7mm Nut Driver Safety Glasses
Small Flat-head Screwdriver (2 to 2.4 mm or 3/32″ tip size, 60 mm long)
INSTALLATION INSTRUCTIONS
A. ADJUST THE REGULATOR
a) Disconnect all electrical power, at the main circuit breaker or fuse box.
b) Shut off the gas supply to the cooktop by closing the manual shut-off valve.
c) Adjust the pressure regulator by doing the following:
1) Unscrew the regulator cap with the wrench (see Figure 19).
Figure 19
2) This is how the retainer pin looks for Natural Gas usage (see Figure 20).
Figure 20