Installation Manual
28
29
9 If you have rec
essed cabinets:
• Make two filler blocks out of scrap wood pieces the size of shaded areas H.
They must be as thick as the depth of the cabinet recess.
• Drill 5/8" holes in the filler blocks to align with points A and B.
Filler blocks
•
Align the blocks with the corresponding holes in the cabinet. They
should be at the same level as the bottom edge of the cabinet frame.
10 Remove the template.
You’ll need:
Top Cabinet Template
Electric drill with 1/2” and 5/8”
bits
Duct tape
Scissors
(recessed cabinets only)
Safety goggles
Saw
(saber, hole, or keyhole)
Ruler or tape measure
Filler blocks or scrap wood pieces
(for recessed cabinets only)
Step 7: Option B - Adapt the micro
wave blower for outside
back exhaust
1 Remove and save the five screws that hold the blower unit in the
microwave.
2 Carefully pull out the
blower unit. The wires will extend far enough to let you
adjust the blower unit. Do not disconnect the wires.
Blower plate and adapter
screws
Blower motor screw
Back of microwave
Blower unit
Blower plate and adapter
screw
Warning
Do not pull or stretch the blower unit wiring. Make sure that the wires are not
pinched.
3 Cut out the vent holes with tin snips.
Blower unit
Vent hole covers