Owner Manual
16 17
14
15
Dimension & Clearance
Dimension & Clearance
36” Gas Range
Clearance
Condition
Minimum
clearance allowed
Clearance between the top of the cooking surface and the bottom wood
or metal cabinet that is protected by not less than:
1/4-inch-thick flame-retardant mill-
board covered with not less than:
o
No. 28 MSG sheet steel or
o
0.015-inch-thick stainless steel or
o
0.024-inch-thick aluminum or
o
0
.
020-inch-thick copper
24”
40”
Top Hood and Cabinet Specifications
Condition
Minimum
clearance allowed
Clearance between the top of the cooking surface and the bottom of an
unprotected wood or metal cabinet for any model other than
EPGR486G (NOTE: This will apply to most installations).
30”
Clearance between the top of the cooking surface and the bottom wood
or metal cabinet that is protected by not less than:
1/4-inch-thick flame-retardant mill-
board covered with not less than:
o
No. 28 MSG sheet steel or
o
0.015-inch-thick stainless steel or
o
0.024-inch-thick aluminum or
o
0
.
020-inch-thick copper
24”
Duel fuel ranges clearance between the top of the cooking surface and the
bottom of an unprotected wood or metal cabinet for model EPGR486G
40”