Electrical Installation 
All model ovens on the front cover are dual rated, designed to be connected to 
Either 208/240V AC ,60Hz, 3 wire , two-phase power supply. 
The  electrical  supply  should  be  3-wire  two-phase  AC.  Install  a  suitable  conduit  box(not  furnished).  An 
appropriately-sized, U-listed conduit connector must be used to correctly attach the conduit to the junction box. 
Important:  Local  Codes  may  vary; installation, electrical  connections and  grounding  must  comply with  all 
applicable local codes.
lf local codes permit grounding through the electrical supply neutral, connect both the white neutral wire and the 
bare ground wire from the oven to the white neutral electrical supply wire. 
Three-wire Connection 
Connect red wire from oven to red wire injunction box. 
    Connect black wire from oven to black wire in junction box. 
Connect green ground wire from oven to gray neutral wire in junction box. 
The conduit cable, where connected at the oven, swivels. Rotate conduit cable upward (or downward) and direct 
through hole prepared in cabinet to attach to J-Box. 
To  maintain  serviceability,  the  flex  conduit  must  not  be  shortened  and  should  be  routed  to  permit  temporary 
removal of the oven. 
Circuit Required 
208V,60Hz 
240V,60Hz 
12AMP 
15AMP 
Cable from
power supply
Cable
from oven
Grounded Neutral
U.L.-Listed conduit connector
Black wires
Red wires
Green wires
Junction box