SLR • SLC • SLD INSTALLATION GUIDE ® OPERATOR SPECIALTY COMPANY, INC. CASNOVIA, MI 49318 • U.S.A. UL325 COMPLIANCE REQUIRES THE USE OF CONTACT EDGES OR PHOTOELECTRIC CONTROLS ON ALL AUTOMATIC OR REMOTELY-CONTROLLED GATE OPERATORS. Oct. 2005, Rev.
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE TABLE OF CONTENTS PRE-INSTALLATION INFORMATION Gate Operator Classifications ......................................................................................................................................................... 3 Safety Information and Warnings .................................................................................................................................................... 3 Pre-Installation Information .......................
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE SAFETY INFORMATION AND WARNINGS GATE OPERATOR CLASSIFICATIONS All gate operators can be divided into one of four different classifications, depending on their design and usage. Read the following before beginning to install OSCO slide gate operators: Class I: Residential A vehicular gate operator (or system) intended for use in a home of one to four single-family dwellings, or a garage or parking area associated therewith. 1.
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE WIRING SPECIFICATIONS 1. Select from the chart at the bottom of this page corresponding to the model, voltage and horsepower rating of your operator. 6. Connect power in accordance with local codes. All power wiring should be done by a licensed electrician. The green ground wire must be properly connected. 2. The distance shown on the chart is measured in feet from the operator to the power source. DO NOT EXCEED THE MAXIMUM DISTANCE.
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE PAD MOUNTING INSTRUCTIONS FOR MODELS SLR, SLC & SLD Before installing, make sure the gate rolls or slides freely, and that all exposed rollers are properly covered. The gate must be covered with fabric with openings no larger than 2 1/4” in size, to a minimum height of 48 inches above ground level. On picket-style gates, if pickets are spaced less than 2 1/4” apart, mesh is optional. A SEPARATE PEDESTRIAN GATE IS REQUIRED FOR ALL PEDESTRIAN TRAFFIC.
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE GATE BRACKET AND CHAIN ASSEMBLY INSTRUCTIONS Numbered items in these drawings are for instructional reference only. For actual part numbers, go to the parts lists in the back of this booklet. Assemble the other gate bracket on the rear edge of the gate, using the same process as you did with the front gate bracket. Once this is done, take the other chain pin, spring and jam nuts and assemble with the end of drive chain and the other master link.
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE VENT PLUG INSTALLATION Gear reducers used in OSCO gate operators will have solid plugs installed prior to shipment in order to keep the oil inside from spilling out during shipping. A vent plug has been provided to replace this plug during installation. This plug will look similar to the ones shown below. Some models may have a vent plug with a breather pin. This pin should be removed after installing the operator.
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE ELECTRICAL CONNECTION AND ADJUSTMENTS Power supply must be of correct voltage and phase. Always disconnect power from operator before servicing. Keep clear of gate during operation. All OSCO gate operators are supplied with a power disconnect switch to turn on and off the power supply available to the operator. Incoming power should be brought into the operator and connected to the labeled pigtails in the disconnect box following wiring specifications on page 4.
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE CONTROL BOARD ADJUSTMENTS LIMIT SWITCH L.E.D.s LIMIT SWITCH CONNECTOR TERMINAL STRIP #1 CONNECTOR 3A Fuse oard rol B Cont h DC wit rd r Boa Moto 2A Fuse TERMINAL STRIP #2 CONNECTOR DIAGNOSTIC L.E.D.
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE TERMINAL CONNECTION DESCRIPTIONS TERMINALS FUNCTION DESCRIPTION OF FUNCTION 24VAC 24VAC N 24VAC Provides 24Volt AC power for accessories. Note: DC models will NOT have 24Volt AC power available. 24VDC+ 24VDC- COMM. 24VDC Provides 24Volt DC power for accessories. 1&4 OPEN Opens the operator. Several accessories such as button stations, keypads, transmitters and card readers can be wired to open. 3&4 CLOSE Closes the operator.
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE CURRENT SENSING ADJUSTMENTS Because gates vary in construction and may have different force requirements in the open and close directions to move, the OSCO control board has separate Multi-turn potentiometers for adjusting in both directions independently. The adjustment should be set light enough to maintain minimal force (50-75 lbs.) should an obstruction occur, but high enough to keep the gate moving under normal conditions without interruption.
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE ONBOARD L.E.D. INDICATOR DESCRIPTIONS Control Board L.E.D. Indicators: OPEN This indicator is lit when an open signal is present. This signal can come from such devices as button stations, radio receivers, keypads and telephone entry systems. CLOSE This indicator is lit when a closed signal is present. This signal typically comes from three-button stations. STOP This indicator is lit when there is a break in the stop circuit.
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE IMPORTANT NOTES FOR INSTALLATION OF MASTER/SLAVE APPLICATIONS When setting up Master/Slave gate operators, it is best to make adjustments and run each operator individually. To do this, simply: a. Set Dip Switch #4 to proper hand of operation (right-hand or left-hand) b. Set Dip Switch #8 as Master (off) Run each operator making current sensing adjustments as necessary, as indicated on the Control Board Adjustments page of this installation guide.
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE CHARGER BOARD SLEEP MODE When primary AC power is not available, the operator will continue to operate in battery only mode if the charger board is set in its RUN mode (see Battery Backup Charger Configuration). Accessories wired into the operator will continue to draw power, even when the operator is not opening or closing the gate. This can dramatically reduce the amount of standby time available from the batteries.
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE CONTROL and ACCESSORY CONNECTION ILLUSTRATIONS - 15 -
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE CONTROL and ACCESSORY CONNECTION ILLUSTRATIONS - 16 -
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE CONTROL and ACCESSORY CONNECTION ILLUSTRATIONS - 17 -
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE CONTROL and ACCESSORY CONNECTION ILLUSTRATIONS AC MODELS ONLY - 18 - 12-06-12
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE LOOP LAYOUT ILLUSTRATION Refer to Connection Descriptions on page 10 and Loop Accessory Connections on page 18 for details.
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE EDGE LAYOUT ILLUSTRATION #1 Refer to Connection Descriptions on page 10 and Contact Edge Connections on page 17 for details.
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE EDGE LAYOUT ILLUSTRATION #2 Refer to Connection Descriptions on page 10 and Contact Edge Connections on page 17 for details.
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE PHOTO EYE ILLUSTRATION Refer to Connection Descriptions on page 10 and Photo Eye Connections on page 17 for details.
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE PICKET GATE ILLUSTRATION Refer to Connection Descriptions on page 10 and Accessory Connections on pages 15-18 for additional details.
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE TRACK GATE ILLUSTRATION - 24 -
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE TROUBLESHOOTING Operator fails to start: A. If the operator has been running a large number of cycles, the motor may have gotten hot and tripped the overload. Allow the motor to cool down and the overload will reset automatically. B. Make sure you have power at the master distribution panel and that the power has not been turned off. C. The secondary fuse on the control board may have blown.
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE MODEL SLR MECHANICAL PARTS EXPLODED VIEW - 26 - 10-04-6
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE MODEL SLR MECHANICAL PARTS LIST REF NO. PART NO.
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE MODEL SLC MECHANICAL PARTS EXPLODED VIEW - 28 - 10-04-6
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE MODEL REF NO. 1 SLC MECHANICAL PARTS LIST PART NO.
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE MODELS REF NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 SLR • SLC CONTROL BOX PARTS LIST PART NO. DESCRIPTION 2100-1778-PLT 2100-1762 2100-1761 2300-735 2200-122 2500-1948 2510-268 2500-1946 2510-244 2510-370 2510-249 2510-250 2510-261 2500-071 2500-212 2500-791 2300-696 2200-940 Control Box Wrapper Terminal Strip Bracket, output side Terminal Strip Bracket, input side Heyco Bushing, 1.09 diameter Heyco Bushing, .
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE MODEL SLD MECHANICAL PARTS EXPLODED VIEW - 31 - 10-04-6
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE MODEL SLD MECHANICAL PARTS LIST REF NO. PART NO. DESCRIPTION 1 2300-907 Operator Cover 2510-354 2500-2240 2500-2241 Plunger Reset Assembly Plunger Reset Button Plunger Extension only 2200-790 Lock for Cover, with Keys 2 2A 3 4 2110-796 2100-2006 2100-2055 2100-1985 7 7A 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 PART NO.
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE MODEL SLD CONTROL BOX PARTS LIST PART NO. DESCRIPTION REF NO. 1 3 4 5 6 2100-1778-PLT 2100-1762 2100-1761 2200-122 2500-1948 Control Box Wrapper Terminal Strip Bracket, output side Terminal Strip Bracket, input side Heyco Bushing, .
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE BATTERY MAINTENANCE The gel-cell batteries in this operator require no routine maintenance. For assured continued performance, they should be replaced every year. If power is to be removed for one week or more, disconnect the negative wire from the batteries as this will prevent deep discharging. Fully charge before use after storage or upon initial installation.
MATERIAL SAFETY DATA SHEET MOBIL SHC 634 1. PRODUCT AND COMPANY IDENTIFICATION PRODUCT NAME: MOBIL SHC 634 SUPPLIER: EXXONMOBIL CORPORATION 3225 GALLOWS RD. FAIRFAX, VA 22037 24 - Hour Health and Safety Emergency (call collect): 609-737-4411 24 - Hour Transportation Emergency (Primary) CHEMTREC: 800-424-9300 Product and MSDS Information: CHEMTREC: MSDS Fax on Demand: MSDS Internet Website: 800-662-4525 800-424-9300 703-846-6691 202-483-7616 613-228-1467 http://emmsds.ihssolutions.com 2.
3sso Imperial Oil MATERIAL SAFETY DATA SHEET Date Prepared: June 12, 1997 Supersedes: February 02, 1996 MSDS Number: 08068 Cette fiche signaletique ast aussi disponible en francais 1. PRODUCT INFORMATION Product Identifier: ESSO GEAR OIL GX 75W-90 Application and Use: Transmission adn gear lubricant. Product Description: Mixture of paraffinic and naphthenic hydrocarbons (saturated and unsaturated), and additives.
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 37 -
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE PREVENTATIVE MAINTENANCE IMPORTANT! • Always disconnect power from operator before servicing. • Keep clear of gate during operation. GENERAL: OSCO gate operators are designed for many years of trouble-free operation and, under recommended operating conditions, will require only minimal maintenance. To ensure that your unit is ready for operation at all times--and to preclude serious damage or failure--inspect the unit systematically.
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE This page intentionally left blank.
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE GATE OPERATOR INSTALLATION CHECKLIST INSTALLER CUSTOMER ________ ________ 1. The gate has been checked to make sure it is level and moves freely in both directions. ________ ________ 2. Potential pinch areas have been guarded so as to be inaccessible OR have contact and/or non-contact obstruction sensing devices installed. ________ ________ 3.