User guide

NOTE:
You
may have different numbers, but the controller code
version should
be
17.3
or
later.
4.
HEAD SERVO CHECK
Press 4 and the screen displays:
CORVUS DRIVE #
(1-4)
? _
Press 1
(or
the drive number,
in
case
of
add-on physical Corvus
drives). The read/write heads
of
the Corvus disk will rapidly move
from the outer edge
to
the center of the disk, producing a whirring
sound. This test verifies that the disk reads data and that the disk
heads move properly.
NOTE: This test continues indefinitely until stopped by holding
down
the control key and pressing C
«CNTL>C).
Approxi-
mately one minute
of
this test should
be
enough
to
check the
disk.
5.
MANUAL
CONTROLLER DIAGNOSTIC
Press 5 and the screen displays:
WARNING
THIS· TEST
CAN CAUSE LOSS OF USER DATA
__
(IF USED IMPROPERLY)
THE
COMMAND
FORMAT IS:
R - READ A BYTE FROM THE CONTROLLER
WXX
- WRITE HEX BYTE TO CONTROLLER
S - READ CONTROLLER STATUS
E - EXIT TEST
NOTE:
This test should be performed ONLY under the direction
of qualified Corvus
Systems Customer Service representatives.
6.
UPDATE CONTROLLER CODE
Press 6 and the screen displays:
CONTROLLER CODE FILE NAME (COVBXX.CLR) :
40