Installation guide
Second, the cable
can
only be 1000 feet
005
m)
long.
If
the network
is
going to be longer
than
1000 feet, talk to a Corvus dealer. With
Corvus Active
Junction
Boxes, a network
can
be
up
to
4000 feet
(121
9
m)
long.
After planning the network,
put
the cable
down
accordingly. The type
of
cable to use
is
unshielded, 20-gauge twisted-pair wire. This
is
available from Corvus
and
most electronics
stores. Corvus recommends Belden
TM
type
8205
VW-l wire for a
network
cable.
TERMINATING THE CABLE
1.
2.
After installing the network
trunk
cable close
off the ends
with
tap boxes
and
resistors.
Remove
the
insulation
from
one
end
of
the
cable.
Use
a knife to cut through the outer insulation
at one
end
of the OMNINET cable. Take off
about
1.5
inches
(4
cm) of the insulation. Do
not remove the insulation from the inner wires.
Pull
apart
a
tap
box.
OMNINET
Cable
17