upB
To setup UPB, you will need to download the UPB UPStart utility from PCS at http://www.
pcslighting.com/.
Once you have setup your lights and scenes using the UPB UPStart utility, you will then export
the devices in the utility, and import the le into the Cortexa.
iNsTeoN
Install devices as per manufacturer’s instructions. The process to congure devices in the
Cortexa is called enrollment and is performed as follows;
Hold the “set” button on the Insteon Powerlink module for 10 seconds, then put the Insteon
device to be congured in “setup” mode. Refer to the manufacturer instructions on how to
do this.
The device will now appear in the Cortexa Device Insteon Group. Go to the Edit Devices
screen and move the device to the Area in which it is installed. The device is now congured
and ready to be controlled and written into events. Refer to the Cortexa Insteon Installation
Guide for more detailed information.
luTroN radio ra
Install devices per manufacturers instructions. Having congured the devices and scenes
within the Lutron system, they now need to be entered in the Cortexa. Carefully note which
Lutron Radio RA switch number corresponds to the physical location of each device.
Similarly, for scenes that have been created in Lutron, note all scene numbers for input to
the Cortexa.
To congure the device into the Cortexa, go to the Add Devices screen. Select Radio RA and
enter the address and area data. In order to congure a scene, enter that scene number
as a Phantom button.