User's Manual
File : CS-SUP-MUTI-WTHERMAPP-E01.sxw
6 MODIFICATION OF THE INTERNAL PARAMETERS
6.1 INTERNAL PARAMETERS LIST ACCESSIBLE BY RADIO COMMANDS
6.1.1 Parameters common to all WAVETHERM versions
The table below describes the internal parameters accessible by standard read and write commands.
N° Description
Size
(in bytes)
Access
right
Default value
Hexa. Decimal
0x01 Operating Mode 1 R/W
Depending of the
module used (see 6.1.5)
0x02 WakeUp system status word 1 R/W 0 0
0x03 Default WakeUp period (in second) 1 R/W 0x01 1
0x04 Start time for 1
st
time window 1 R/W 0x07 7
0x05 WakeUp period for 1
st
time window (in second) 1 R/W 0x01 1
0x06 Start time for 2
nd
time window 1 R/W 0x12 18
0x07 WakeUp period for 2
nd
time window (in second) 1 R/W 0x01 1
0x08 Enalbe time windows by day of the week 1 R/W 0xFF 255
0x09 Enable WakeUp periods by day of the week 1 R/W 0x00 0
0x0A number of loop of the datalogging storage table 1 R 0x00 0
0x0B Number of temperature values stored in the table (LSB first) 2 R 0x0000 0
0x19 Numbers of retries of transmission of alarm frames 1 R/W 0x03 3
0x1A Delay between two retries of transmission of alarm frames 1 R/W 0x3C 60
0x20 Application Status 1 R/W 0x80 128
0x22 Alarm Configuration byte 1 R/W 0x00 0
0x80 Measurement Period (datalogging in time steps) 1 R/W 0x13 19
0x81 Start hour of the datalogging in time steps 1 R/W 0x08 8
0x82 Day of the week, or of the month (datalogging) 1 R/W 0x01 1
0x83 Time of measurement (datalogging once a week, or once a month) 1 R/W 0x08 8
0x85 Group number to use in polling mode 1 R/W 0x00 0
0x90 Date of detection of end of battery life 6 R/W 0 0
0xA1 Firmware version 1 R - -
0xA2 Battery life duration counter 2 R
Depending of the power
supply profile
0xB0 Number of repeaters used to transmit an alarm frame 1 R/W 0x00 0
0xB1 Address of the 1
st
repeater used to transmit an alarm frame 6 R/W - -
0xB2 Address of the 2
nd
repeater used to transmit an alarm frame 6 R/W - -
0xB3 Address of the 3
rd
repeater used to transmit an alarm frame 6 R/W - -
0xB4 Address of the recipient of the alarm frame 6 R/W
0x010A030
000BD
-
WaveTherm modules – application handbook page 21 of 65