User's Manual

Table Of Contents
RTM Elster AMCO applicative PFS Coronis Systems
TABLE OF CONTENTS
1.DEFINITIONS................................................................................................................................................4
2.INTRODUCTION...........................................................................................................................................7
3.REFERENCE DOCUMENTS.........................................................................................................................7
4.RTM ELSTER AMCO CONFIGURATION ACCESS......................................................................................8
4.1.Radio exchange principle............................................................................................................................8
4.2.Control bytes.............................................................................................................................................10
4.2.1.Operating Mode...........................................................................................................................10
4.2.2. Alarm Configuration.....................................................................................................................10
4.2.3.Application Status........................................................................................................................10
4.2.4.Leakage Detection Status............................................................................................................11
4.3.Meter reading sampling period configuration.............................................................................................11
5.RTM ELSTER AMCO FUNCTIONALITIES.................................................................................................12
5.1.Fixed Network/Walk By/ Drive By switching method.................................................................................12
5.2.Datalogging management.........................................................................................................................13
5.2.1.Datalogging mode activation........................................................................................................13
5.2.2.Datalogging in time steps.............................................................................................................14
5.2.3.Datalogging once a week.............................................................................................................14
5.2.4.Datalogging once a month...........................................................................................................14
5.3.RTM-Register interface.............................................................................................................................15
5.3.1.Pulse register three wire interface................................................................................................15
5.3.2.Encoder three wire interface........................................................................................................16
5.4.RTM-register pairing.................................................................................................................................17
5.4.1.Programming current register reading (pulse register only).........................................................17
5.4.2.Programming pulse value (pulse register only)............................................................................17
5.4.3.Programming meter model (pulse register only)..........................................................................17
5.4.4.Encoder model detection.............................................................................................................18
5.4.5.Encoder Unit (Encoder register only)...........................................................................................18
5.5.RTM reading management.......................................................................................................................19
5.5.1.Current register reading...............................................................................................................19
5.5.2.Daily consumption profile reading................................................................................................19
5.5.3.Datalogging table reading............................................................................................................20
5.5.4.Time Of Use (TOU) buckets configuration and readings..............................................................21
5.6.Automatic Radio transmission (pseudo bubble up mode - Fixed Network Only)..........................22
5.7.Leak detection management.....................................................................................................................23
5.7.1.Residual leak detection................................................................................................................23
5.7.2.Extreme leak detection................................................................................................................24
5.8.Tamper detection (pulse register only)......................................................................................................25
5.9.Communication and reading error detection (encoder only)......................................................................25
5.9.1.Encoder communication error......................................................................................................25
5.9.2.Encoder reading error detection...................................................................................................25
5.10.Low Battery Warning detection................................................................................................................26
5.11.Faults or Flow Problems automatic transmission....................................................................................27
sEVO RTM-UserMan-E02 2