User's Manual

Table Of Contents
Document : EvoModule1- UserMan.sxw
EXAMPLE : configuration of the repeaters table, and activation of error frames.
Between WaveCard (exchange instigator), and the recipient equipment, we have a repeater
equipment(radio address : 0X AA AA AA AA AA AA). In addition, we must authorize the error frame, in order
to determine which distant equipment caused the error.
Writing new parameters
repeaters list configuration (Request/Response mechanism)
Request from the host to the WaveCard (
REQ_WRITE_RADIO_PARAM)
HEADER
SYNC STX LENGTH
CMD
DATA
Parameter
number
Parameter data
CRC ETX
0xFF 0x02 0x0C 0x40 0x07 0x01 ; 0xAAAAAAAAAAAA 0xXXXX 0x03
Response from the WaveCard to the host (
RES_WRITE_RADIO_PARAM)
HEADER
SYNC STX LENGTH
CMD
DATA
Status of the update
CRC ETX
0xFF 0x02 0x05 0x41 0x00 0xXXXX 0x03
Activation of the error frames (Request/Response mechanism)
Request from the host to the WaveCard (REQ_WRITE_RADIO_PARAM)
HEADER
SYNC STX LENGTH
CMD
DATA
Parameter
number
Parameter data
CRC ETX
0xFF 0x02 0x06 0x40 0x0E 0x01 0xXXXX 0x03
Response from the WaveCard to the host (RES_WRITE_RADIO_PARAM)
HEADER
SYNC STX LENGTH
CMD
DATA
Status of the update
CRC ETX
0xFF 0x02 0x05 0x41 0x00 0xXXXX 0x03
EvoModule1 Handbook page 16 of 68