User's Manual

RTM Elster AMCO applicative PFS Coronis Systems
Param
ID
Description
Size
in
bytes
Access
Right
(Pulse
register)
Access
Right
(encoder
register)
Default value
(Hexa)
Restriction
on
parameters
Battery life
0x50
Battery life duration counter 3 R R
TBD by CORONIS -
0x51
Date end of battery life detection 7 R R
0x01010101010101
An erroneous
date must be
rejected
Configuration of alarm
0x57
Alarm Window configuration parameter
1
R/W R/W
0x00
See Section
§xxx
0x58
Alarm Configuration parameter
1
R/W R/W
0x00
From 0x00 to
0x3F
0x59
Number of repeaters
(used only with manual network construction)
1
R/W R/W
0x00
From 0x00 to
0x03
0x5A
Address of the 1
st
repeater
(used only with manual network construction)
6
R/W R/W
0x000000000000
0x5B
Address of the 2
nd
repeater
(used only with manual network construction)
6
R/W R/W
0x000000000000
0x5C
Address of the 3
rd
repeater
(used only with manual network construction)
6
R/W R/W
0x000000000000
0x5D
Address of the recipient of the alarm frame
(used only with manual network construction)
6
R/W R/W
0x000000000000
TOU buckets
0x60 TOU buckets configuration parameter 7 R/W R/W 0x00000000000000
See Section
§5.6
Pseudo bubble up feature
0x68
Starting hour, minute and second of the pseudo
bubble up mechanism
3 R/W R/W
0x080000
An erroneous
date will be
rejected
0x69
Step time of pseudo bubble up transmission 1 R/W R/W
0x06
See Section
§5.6
0x6A
First byte : Data length of bubble up command
buffer
Other bytes : bubble up command buffer (use to
write request command)
7 R/W R/W 0x01030000000000
The first byte
should not be
higher than 6
and the
command
should be
correctly
written
0x6B
Maximum cancellation Timeout (in seconds): this
time is needed when a process take a too long time
and shift the current RTC compare to the computed
RTC of bubble up emission.
1
R/W R/W
0x05
From 0x01 to
0x0A
EVO RTM-UserMan 68