5.12.6.alarm frame acknowledgment
The remote device must send an acknowledgment frame (command 0xC0) to confirm reception of the alarm
frame and end dialog.
Acknowledge request data format
Applicative command Alarm Status
1 byte 3 bytes
0xC0 Same as received in the alarm frame
If the RTM Elster AMCO does not receive this acknowledgment, it re-transmits the alarm frame several time,
with a delay between each retransmission. The delay, and the number of retries depend on the equipment
type used.
Number of retries of alarm sending 7 times
Delay between each retransmission
1
st
retry :1 minutes, 2
nd
retry : 15 minutes, 3
rd
retry : 45 minutes,
4
th
retry : 90 minutes, 5
th
retry : 180 minutes, 6
th
retry : 360 minutes,
7
th
retry : 720 minutes
ATTENTION:
As mentioned above in this document, it is not recommended to enable alarm frames when RTM
Elster AMCO is programmed to send periodically its information. This could cause collision on
the radio medium and so lead to a loss of information coming from the RTM.
EVO RTM-UserMan 63