Technical data
4
SERVICING WARNING WORK SAFELY
Where necessary disconnect from electricity and gas before starting.
Check range is safe when you have finished.
Servicing Notes
When servicing or replacing gas carrying components disconnect from gas before commencing operation and
check range is gas sound after completion. When checking for gas leaks use a liquid leak detector at all joints and
connections to check for leaks in the system. Use a product specifi cally manufactured for leak detection. Leak
testing of the range shall be conducted in accordance to the manufacturer’s instructions.
CAUTION: DO NOT USE A FLAME TO CHECK FOR GAS LEAKS.
When using test pressures greater than ½ psig (3.5kPa) to pressure test the gas supply system of the residence,
disconnect the range and individual shut-off valve from the gas supply piping. When using test pressures of ½ psig
(3.5kPa) or less to test the gas supply system, simply isolate the range from the gas supply system by closing the
individual shut-off valve.
Do not use re-conditioned or unauthorized gas controls.
Disconnect from electricity supply before commencing servicing, particularly before removing any of the
following: control panel, side panels, cooktop tray, or any of the electrical components or cover boxes. Before
electrical reconnection make sure the range is electrically safe.
Note – If not specifi cally stated, references to left hand and right hand oven are as viewed from the front of the
range.