Technical data
32
SERVICING WARNING WORK SAFELY
Where necessary disconnect from electricity and gas before starting.
Check range is safe when you have finished.
Technical Data
This range is supplied set for Natural gas.
A conversion kit from Natural Gas to Propane gas is included.
INSTALLER: Please leave these instructions with the User.
DATA BADGE LOCATION: Inside base of drawer cavity - remove drawer. For removal of drawer see installation
instructions.
Country of Destination: USA/Canada
Gas Electric
Natural Gas 4.0” W.C (10 mbar) 240V 60Hz
Propane 10.0” W.C (25 mbar)
(See appliance data badge for test pressures)
Dimensions
Overall height minimum 35 13/16” (91 cm) maximum 36 7/8” (93.7 cm)
Overall width 43” (109.2cm) See ‘Positioning the Range’
Overall depth 28 5/8” (72 .5cm).
Space for fi xing See ‘Positioning the Range’
Minimum space above cooktop 31.5” (80cm)
Connections
Gas : Electric:
½” NPT at rear right-hand side
240 V 60 Hz
Ratings
Cooktop
Natural Gas Propane Gas
Input Orifice Screw Input Orifice Screw
Center burner 17,500 Btu/hr 205 82 17,500 Btu/hr 118 49
Large Burners 12,000 Btu/hr 150 70 12,000 Btu/hr 99 38
Right hand front Burner 6,000 Btu/hr 112 53 6,000 Btu/hr 68 31
Gas burner inputs based on Gross Calorifi c Value