Technical data

7

When servicing or replacing gas carrying components
disconnect from gas before commencing operation and
check range is gas sound after completion. When checking
for gas leaks use a liquid leak detector at all joints and
connections to check for leaks in the system. Use a product
specifically manufactured for leak detection. Leak testing
of the range shall be conducted in accordance to the
manufacturers instructions.


When using test pressures greater than ½ psig (3.5kPa)
to pressure test the gas supply system of the residence,
disconnect the range and individual shut-off valve from
the gas supply piping. When using test pressures of ½
psig (3.5kPa) or less to test the gas supply system, simply
isolate the range from the gas supply system by closing the
individual shut-off valve.
Do not use re-conditioned or unauthorised gas controls.
Disconnect from electricity supply before commencing
servicing, particularly before removing any of the following:
control panel, side panels, cooktop tray, or any of the
electrical components or cover boxes. Before electrical
reconnection make sure the range is electrically safe.

Disconnect from electricity and gas before servicing. Check range is safe when you have finished.