Technical data
7
When servicing or replacing gas carrying components
disconnect from gas before commencing operation and
check range is gas sound after completion. When checking
for gas leaks use a liquid leak detector at all joints and
connections to check for leaks in the system. Use a product
specifically manufactured for leak detection. Leak testing
of the range shall be conducted in accordance to the
manufacturer’s instructions.
When using test pressures greater than ½ psig (3.5kPa)
to pressure test the gas supply system of the residence,
disconnect the range and individual shut-off valve from
the gas supply piping. When using test pressures of ½
psig (3.5kPa) or less to test the gas supply system, simply
isolate the range from the gas supply system by closing the
individual shut-off valve.
Do not use re-conditioned or unauthorised gas controls.
Disconnect from electricity supply before commencing
servicing, particularly before removing any of the following:
control panel, side panels, cooktop tray, or any of the
electrical components or cover boxes. Before electrical
reconnection make sure the range is electrically safe.
Disconnect from electricity and gas before servicing. Check range is safe when you have finished.