Technical data
6
A. Check continuity of h.t wire from spark module to
spark electrode.
B. Visually check for spark tracking from h.t. components
to earthed metal (e.g. fixing brackets).
C. Check ceramic insulation for cracks.
D. Unplug high tension wire from spark module - with
meter on
�Ω x 100 scale ensure resistance from
disconnected wire to any ground point is infinity (∞).
E. Check spark gap and electrode alignment.
Rectify any faults.
START
PUSH IN BURNER CONTROL KNOB
ELECTRODE DOES NOT SPARK
CHECK NO RESISTANCE BETWEEN
L1 ON TERMINAL BLOCK AND L1 ON
SPARK GENERATOR MODULE.
REPEAT PROCEDURE FOR L2.
DOES ELECTRODE SPARK
CHANGE SPARK MODULE
IGNITION SYSTEM NOW IN
WORKING ORDER
DOES BURNER LIGHT?
CHECK GAS SUPPLY TO RANGE
AND BURNER COMPONENTS
Correct any wiring faults.
Ensure connections are clean
and tight. Use appropriate procedure
to check control valve switch.
NO
YES
YES
YES
NO
NO
CLEAR
CLEAR