Installation Instructions
E62-M3-L
7 Bands SISO
© E62-M3-L | 5 of 6
Technical Specifications
System
Maximum RF Bands per Access Unit
4
Maximum RF Bands per Remote Unit
7
Maximum Access Units per System
3 (1 x Primary A3 / 2 x Secondary A3)
Maximum E3s per Primary A3
8
Maximum M3RUs per E3
14
Maximum Cascaded Level
6
Maximum IBW
200MHz
Band Selective Mode
≤100MHz, @1MHz step
Channel Selective Mode
LTE: 5/10/15/20 MHz
NR: 5/10/15/20/30/40/50/60/70/80/90/100 MHz
Fiber transmission Capacity
48 Basic Units
Filter Bandwidth
≤25M
25<BW≤50M
50<BW≤75M
75<BW≤100M
Basic Units Occupied
1
2
3
4
M3RU DSP Capacity
12 DSP Units per Band
Filter Bandwidth
≤25M
25<BW≤50M
50<BW≤75M
75<BW≤100M
DSP Units occupied
1
2
4
4
Maximum Filters Supported per Band
4
System Delay Adjustment
Up to 80.00µs
System Delay (A3+E3+M3)
12µS
VSWR
<1.6
Supported Bands
Band
3GPP Band
Downlink
Uplink
Max Band Width
600
71
617-652
663-698
35
700
12 & 13 & 14
728-768
698-716&776-798
40
800/850
26
862-894
817-849
32
1900(PCS)
25
1930-1995
1850-1915
65
EAWS
66
2110-2200
1710-1780
70
WCS
30
2350-2360
2305-2315
10
2500
41
2496-2690
2496-2690
194
Forward Path (Downlink)
Bands
600 & 700 & 800/850
1900 & EAWS & WCS
B41
Output Power per Band
33 ± 2dBm
37 ± 2dBm
39 ± 2dBm
Maximum Gain
33 ± 3dB
37 ± 3dB
39 ± 3dB
Maximum Input Power
+15dBm (with AGC operating) / 0dBm (without AGC operating)
EVM
<3.5% @ 256 QAM
Manual Attenuation Control
35dB @ 1dB/step (A3: 20dB, M3RU-L: 15dB)
Ripple removed