6.7 Traps
Trap Name Severity Trap Description
maCULowDLRFPowerSet Major Alert for downlink Low RF in VCU
Measured BTS DL input power is less than 5 dBm
maCULowDLRFPowerClear Notify Normal DL input power
maCUHighDLRFPowerSet Major Alert for downlink High RF in VCU
Measured BTS DL input power is 3 dB higher than the
maximum expected power (Adjustment power)
maCUHighDLRFPowerClear Notify Normal DL input power
maApodConnect Notify Alert for APod connection to the VCU
maApodDisconnect Notify Alert for APod disconnection from the VCU
maCUFaultySet Major Alert for general VCU fault
One of the synthesizers of the VCU (UL or DL or
adjustment or ASK) is unlocked
maCUFaultyClear Notify VCU is o.k.
maCUOverTemperatureSet Minor VCU temperature is too high
Measured temperature in VCU is more than 50°c
maCUOverTemperatureClear Notify Temperature is Normal
maCUServiceOff Major Service shutdown in VCU
Service in VCU is off due to user request
maCUServiceOn Notify Notification for service on - Service Off alarm was
cleared
maApodDLAdjustmentSet Major Downlink Low RF in APod
Unit adjustment was failed, more than 35 dB loss in
cable
maApodDLAdjustmentClear Notify Adjustment completed successfully
maApodOverTemperatureSet Minor APod temperature is too high
Temperature is over the threshold
maApodOverTemperatureClear Notify Normal Temperature
maApodApodFaultySet Major General APod malfunction
One of the synthesizers (UL, DL, ASK) is unlocked
maApodApodFaultyClear Notify APod is good
maApodServiceOff Major Service shutdown in APod
Unit RF service is off (according to user request)
maApodServiceOn Notify APod service is ON
maCUMismatchSetupSet Minor Mismatch configuration - wrong APod type connected to
the VCU
maCUMismatchSetupClear Notify Configuration is matched