User's Manual
Navigating the Management Application
40 Voasis™ UMTS/DCS/PCS Installation and Configuration Manual
6.6 VAP Alarms
Define the VAPs related Alarms by choosing the Configuration main tab, then the Alarms tab
and then clicking a VAP:
LED Description
DL RF Pwr Low RED - VAP output power low. Loss of more than 30dB on cable.
Check cable.
GREEN – VAP output power OK.
Over Temperature VAP Temperature(major) -
RED - shall be generated when temperature is above threshold
GREEN - event shall be generated when temperature return to
below threshold
APod Faulty Synthesizer status -
RED - one of the synthesizers (UL or DL) of the service is
unlocked.
GREEN – all synthesizers (UL or DL) of the service are locked
Service Off RED - Service off according to user request
Overall Status Overall status – The overall status of each port reflects the max
severity of its alarms