User's Manual

Navigating the Management Application
38 Voasis™ UMTS/DCS/PCS Installation and Configuration Manual
6.4 Monitor Screen - Active Events
This pane shows the last traps generated by the system, where a RED trap is an active event
and a GREEN trap is a cleared event.
The following tables describe the VCU and VAP Events:
VCU Events
Alarms Description
Downlink Low RF RED - BTS DL input power is at least 20 dB lower than Max
Expected Power defined by the user.
Downlink High RF RED - BTS DL input power is 3 dB higher than Max Expected Power
defined by the user.
VCU Faulty RED - VCU fault. Remove and re-apply power to VCU. If problem
persists, replace VCU.
Mismatch Setup RED – mismatch between VCU type and connected VAP type.
Overall Status Status of highest fault.
Temperature too high The device temperature exceeds a threshold
Connection to VCU RED – connection between APOD and VCU is faulty
Service Shut Down RED - Service off according to user request