User's Manual

Navigating the Management Application
Voasis™ UMTS/DCS/PCS Installation and Configuration Manual 37
6.3.3 Alarms Tab
This tab is a display of the main alarms in the VCU.
To access the Alarms Tab
In the Topology Tree, click the Control Unit, click the Configuration tab at the top of the
window and click the Alarms sub tab.
If one or more alarms occur, the corresponding LED is lit with RED light. If the VCU is OK and no
fault accurse, the Overall Status LED is lit with GREEN light.
Note: All alarms are enabled in this version.
Alarm Description
DL RF Pwr Low DL RF Power is 20dB less than maximum expected
power defined by the user. i.e. if user defined a
maximum power of 30 dBm, the DL RF Pwr Low will be
RED if the measured power is 10dBm or less.
DL RF Pwr High Higher than maximum expected power defined in the RF
Config tab by 3 dB or more.
DL Overpower Protection Not implemented in this version.
Service Off RED - Service off according to user request
CU faulty Hardware fault detected in CU.
Over temperature Temperature of unit exceed normal range.
Overall status Indicates Fault (RED) level or GREEN if there are no
faults.