User's Manual
Navigating the Management Application
36 Voasis™ UMTS/DCS/PCS Installation and Configuration Manual
6.3.2 RF Config Tab
This tab provides the RF configuration parameters of the VCU.
To access the RF Config Tab
Click the Configuration tab at the top of the window and click the RF Config sub tab.
Parameter Description
Service Type Read only. Set according to the unit type – UMTS, PCS or DCS.
Service DL CF* DL center frequency (from BTS). User defined according to
ranges:
• UMTS: 2110 – 2170
• DCS: 1805 – 1880
• PCS: 1930 – 1990
Note: If the frequency that was typed is not in range an error
appears in yellow above the VAPs links buttons.
Service UL CF UL center frequency (from BTS) – corresponding to defined DL
Center Frequency. Automatically assigned by the system
according to the DL frequency.
Max Expected Pin* Maximum expected input power from the BTS. Used for
adjustment procedure. Range: 10 to 33 dBm
Service Control Set to Enable for normal operation, set to Disable to turn VCU
services off
Reset Not implemented in this version.
* Required parameters.