Voasis™ UMTS/DCS/PCS Installation and Configuration Manual 25
7. Click the Alarms tab (at the bottom of the Configuration pane). Verify that all the alarms
are GREEN. Refer to the alarm descriptions in the table following the figure below.
VCU Alarms Description
Alarms Description
DL RF Pwr Low RED - DL RF Power is 20dB less than maximum expected power
defined by the user. i.e. if user defined a maximum power of 30 dBm,
the DL RF Pwr Low will be RED if the measured power is 10dBm or
less.
DL RF Pwr High RED - the input power exceeds the maximum expected power defined
by the user by 3 dB or more.
Overpower
Protection
N/A
VCU Faulty RED - VCU fault. Remove and re-apply power to VCU. If problem
persists, replace VCU.
Overall Status Status of highest fault.
4.5 What Next?
Do not disconnect the WEB management application from the VCU; you will be using it to verify
the connections after all the VAPs are placed in their locations.