22 Voasis™ UMTS/DCS/PCS Installation and Configuration Manual
4.3.3 Setting SNMP Parameters
After opening a telnet session to the corresponding unit using the Lantronix DeviceInstaller (as
explained in section
4.3.2):
1. In the Change Setup menu enter 3 (SNMP Configuration).
Change Setup:
0 Server configuration
1 Channel 1 configuration
3 SNMP configuration
8 exit without save
9 save and exit Your choice 3
2. Set the SNMP Read and Write community names and the SNMP traps destination addresses
(up to three addresses can be defined).
SNMP community name for read (): public
SNMP community name for write (): private
Enter IP addresses for SNMP traps:
1: (000) 192.(000) 168.(000) 10.(000) 22
2: (000) .(000) .(000) .(000)
3: (000) .(000) .(000) .(000)
3. Press Enter to run through the rest of the parameters. When the Setup Menu is displayed
again, select 9 – Save and Exit