User's Manual
VCU Installation and Configuration
18 Voasis™ UMTS/DCS/PCS Installation and Configuration Manual
4.3 VCU SNMP Configuration
In order to enable remote management it is required to configure the VCU SNMP parameters.
The VCU SNMP configuration is performed using the Lantronix DeviceInstaller application –
an external application available on your Setup CD.
4.3.1 Installing the Lantronix DeviceInstaller Application
This section describes how to install the Lantronix Device Installer application.
Note: This external application is provided with your Setup CD and can be downloaded from the
Lantronix web (www.lantronix.com) site at any time free of charge.
To install the Lantronix DeviceInstaller
1. Insert the supplied Setup CD in your computer drive.
2. Run the file Setup.exe and follow the displayed prompts.
3. From the Start menu, select Lantronix, DeviceInstaller.
• If multiple Network Adapters are installed in your system, you may be prompted with
the following dialog (otherwise, the Lantronix main window appears).
• (If prompted), click Yes. A dialog listing the currently available network adapter cards
appears. For example
• Select your network connection and click OK. The Lantronix Main window appears.