User's Manual

Infrastructure Requirements and Layout Planning
12 Voasis™ UMTS/DCS/PCS Installation and Configuration Manual
VAPs 11 and 13 are placed closer to the offices to cover them well but on the open side will
actually cover a much greater area which is why the coverage is larger and shown here more
as an oval than a circle.
The area between VAPs 7 and 14 outside the bathrooms would probably be the lowest
coverage spot in the building because of the bathrooms and stairwell on either side of that
area. If after the system installed, this area is still a little low on coverage, a VAP can be
added, but it may also be covered by VAP 14.
Note: The plan can be modified at any time by moving the units around or by adding units.
The following figure depicts an actual measured quantified coverage of a floor aria planed
according to the above rules
Figure
3-3. Distributed VAPs propagation, 12dBm output power @ 1.8GHz.