Dual-Band MobileAccessVE Instant Coverage Solution User Manual 64
Appendix A - Traps
This section lists the MobileAccessVE Dual-Band Controller and Access Pod Traps.
VE Control Unit (VCU) Traps
Trap Name
Trap Description
vcuChannel_1_DLPowerLow
(Major) Alert for low RF in VCU for Service 1: 15dB less than
max expected power
vcuChannel_1_DLPowerHigh
(Minor) Alert for High RF in VCU for Service 1: 3dB more than
max expected power
vcuChannel_1_ServiceOff
(Major) User set Service 1 to off
vcuChannel_2_DLPowerLow
(Major) Alert for low RF in VCU for Service 2: 15dB less than
max expected power
vcuChannel_2_DLPowerHigh
(Minor) Alert for High RF in VCU for Service 2: 3dB more than
max expected power
vcuChannel_2_ServiceOff
(Major) User set Service 2 to off
vcuFault
(Major) HW failure in VCU
vcuOverTemperature
(Minor) VCU temperature is too high
vcuMismatchType
(Minor) When VCU services types is different than VAP services
types
vcuAdjustment
(Major) When adjustment (for Slave VCU) has failed (cable too
long)
VE Access Pod (VAP) Traps
Trap Name
Trap Description
vapAdjustment
(Major) Cable is too long (over 100m/300ft)
vapChannel_1_ServiceOff
(Minor) User set service 1 to Off
vapChannel_2_ServiceOff
(Minor) User set service 2 to Off
vapFaulty
(Major) The Access Pod is faulty
vapOverTemperature
(Minor) VAP temperature is too high