User's Manual
VCU Unit Installation and Provisioning
Dual-Band MobileAccessVE Instant Coverage Solution User Manual 30
Click Modify and enter the DL central frequency for each service according to the following
ranges:
• EGSM: 925 – 960 MHz
• UMTS: 2110 – 2170 MHz
• PCS: 1930 – 1990 MHz
• PCSG (including G block): 1930 – 1995 MHz
• CELL: 869 - 894 MHz
• DCS: 1805 – 1880 MHz
Note: The Service DL CF dialog displays the relevant range for each service.
Click OK.
Define Max expected power of BTS (0-33dBm)
Define UL system gain for each service (5 to -15dB)
Notes:
1. Max expected Pin and Service CF parameters are service dependent and can be obtained
from your service provider.
2. The remaining parameters are predefined to their default values. (Service Bandwidth is
set to 15 MHz for EGSM, UMTS and CELL and to 20 MHz for DCS and PCS).
3. Any updates of the service Central Frequency definition is sent to all connected VAPs.
11. To verify proper operation of the system, refer to the Alarms sub-tab (in the Config tab).
See following figure.