User's Manual

Dual Band EnCOVER VE™ Instant Coverage Solution User Manual
52
Appendix A - Traps
This section lists the Encover VE™ Dual - Band Controller and Access Pod traps
EnCOVER VE™ Control Unit Traps
No Trap Name Trap Description
1
HeartBeat System heart beat.
2
Service1LowRFcarrier (Major) Alert for low RF in VCU: 15 dB less than max expected power
3
Service1HighRFcarrier
(Minor) Alert for High RF in VCU: 3 dB more than max expected power
4
Service1Off
Major : user setting service to off
5
Service2LowRFcarrier (Major) Alert for low RF in VCU: 15 dB less than max expected power
6
Service2HighRFcarrier
(Minor) Alert for High RF in VCU: 3 dB more than max expected power
7
Service2Off
Major : user setting service to off
8
Control Unit Faulty Major: HW failure in CU
9
OverTemperature Minor: VCU temperature is too high.
10
AbnormalSetup
Minor: Msmatched service types of more than two tiers
11
CU-SlaveDetected Notify: A slave control unit is detected by the Master VCU.
12
CU-SlaveDisconnected Notify: A slave control unit is disconnected from the Master VCU.
Encover VE™ APod Traps
No Trap Name Trap Description
1
AdjustmentSetup
Major: Cable is either too lon
g
(more than 100m) or too short (less than
10m)
2
Service1Off (at APod) Minor: User set service too Off
3
Service2Off (at APod) Minor: User set service too Off
4
APod Faulty Major
5
OverTemperature Minor: APod temperature is too high.
6
APodDetected Notify: A VAP is detected by the VCU.
7
VAPDisconnected Notify: A VAP is disconnected from the VCU.