User's Manual
Navigating the Management Application
Dual Band EnCOVER VEâ„¢ Instant Coverage Solution User Manual 49
The following table provides a description of the RF parameters displayed in the Service RF tabs.
Parameter Description
Type Set according to unit type (e.g. EGSM /UMTS)
Service Control Used to Disable (Off) or Enable (On) the service for the specific VAP
DL Pout Level Low – measured power is below required level
Level 0 - measured power is at required level
Level 1 – measured power is (approx.) 5 dB less than the required level
Level 2 - measured power is (approx.) 10 dB less than the required level
High - measured power is over the maximum required level
UL Pout Level Corresponds to defined DL Pout level
Antenna Select External only if an external antenna is connected to this VAP.
Otherwise, the option should be set to Internal (default).
6.4 Management Tab
6.4.1 Security Tab – Changing Password
The Management - Security tab provides password change options. This tab is common to the
VCU and VAPs.
To set the application password or change an existing password
1. Select the Security option of the Management tab at the top of the window.
2. Click the Modify (Password) button of the User Name whose password is to be modified.
3. Enter the New Password and re-enter in the Confirm New Password field.
4. Click OK.