User's Manual
Navigating the Management Application
Dual Band EnCOVER VE™ Instant Coverage Solution User Manual 48
The following table provides a description of the RF parameters displayed in the Service RF tabs.
Parameter Description
Type Set (read only) according to unit type (e.g. EGSM / UMTS)
DL CF* DL Center frequency (from BTS). User defined, according to connected
service (EGSM / UMTS / CELL / PCS / DCS).
UL CF UL center frequency (from BTS) – corresponding to defined DL Center
Frequency. Automatically assigned by the system according to the DL
frequency.
Max Exp Pin* Maximum expected input power from the BTS. Used for adjustment
procedure. Range: 0-33 dBm. User defined.
Pin Actual measured Pin (read only)
UL System Gain Used for adjusting the UL system gain. Range: -15 dB to +15 dB
Service Control Enables (On)/Disables (Off) the service
* Required parameters to be provisioned by the user.
6.3.6.2 VAP Service RF Tab
To access the Service RF tab
Click the Config tab from the main menu bar and then select the VAP from the network
topology and click the
Service RF
tab. The parameters displayed in Service RF tabs correspond to
the selected element.
Selected
VAP