User's Manual

Navigating the Management Application
Dual Band EnCOVER VE™ Instant Coverage Solution User Manual 45
6.3.4.2 VAP Alarms Tab
When a VAP element is selected in the topology tree, the Alarm tab displays the main alarms in
the unit.
To access Alarms Tab of VAP
In the Topology Tree, click the VAP, click the Config(uration) tab in the menu bar located at
the top of the window and click the VAP Alarms sub tab.
If one or more alarms occur, the corresponding Status indicator is illuminated in RED. If the VAP
is OK and no fault occurs, the Overall Status indicator will show GREEN.
Alarm Description
Service 1/2 Off User has disabled service
DL Adjustment Indicates dB loss over the coax cable (either coax is shorter than
10m or longer than 100m or faulty)
VAP Faulty A fault has been detected in the VAP
Overall temperature Temperature of unit exceeds normal range
Overall status Indicates Fault (RED) level or GREEN if there are no faults