11. To verify proper operation of the system, refer to the Alarms sub-tab (in the Config tab).
See following figure.
12. Verify that all the alarms are GREEN. Refer to the alarm descriptions in the table following
the figure below.
Alarm Description
Service 1 DL RF Pwr Low
RED - DL RF Power is lower than 5dBm.
Service 1 DL RF Pwr High
RED - the input power exceeds the maximum limit and
cannot be attenuated to the required limit. Traffic is
disconnected.
Service 1 Service Off User has disabled service
Service 2 DL RF Pwr Low
RED - DL RF Power is lower than 5dBm.
Service 2 DL RF Pwr High
RED - the input power exceeds the maximum limit and
cannot be attenuated to the required limit. Traffic is
disconnected.
Service 2 Service Off User has disabled service
CU Faulty RED - VCU fault. Remove and re-apply power to VCU or
push the Reset button. If problem persists, replace VCU.
Over Temperature Temperature of unit exceeds normal range.
Mismatch Red – Mismatch of services
Adjust Only relevant to control unit defined as a slave unit:
RED – Indicates dB loss over the coax cable (either coax is
shorter than 10m or longer than 100m or faulty)
Overall Status Indicates Fault (RED) level or GREEN if there are no faults.