User's Manual

Connections I P/N 709C011101 I Page 29
3.5.2.3 Daisy Chaining the AMU modules of Multiple QX Units to a Single SCU-F
NOTE: If installing more than one QX unit, they can be interconnected so that the antenna sense function is
performed by a single AMU (Antenna Monitoring Unit) located inside the QX unit.
Connect one of the two front panel ANT. Sense1 RJ45 connectors of the QX unit directly
connected to the SCU-F DB-15 port to the ANT. Sense1 port of the additional QX unit using
the RJ45 to RJ45 cable provided with the QX (P/N 705900003). It is recommended to connect
the ports closest to each other. See Figure
3-22.
Daisy Chaining AMU to SCU-F Connections
Figure 3-22