User's Manual

ModuLite Installation Guide INSTALLATION
Foxcom Wireless Confidential and Proprietary Information
Document No. 43-93-005-05 y 26
4.5. Protective Earthing
See Figure 14 below, which describes how to connect the ground to the MRC. Connect the GND wire to
the GND of the rack (for a rackmount) or to the GND of the building (for a wallmount).
SIDE VIEW
TOOTH WASHER
FLAT WASHER
HOUSING WALL
WING NUT
GND STANDOFF
TERMINAL LUG
GND WIRE
16 AWG
Figure 14: ModuLite™ GND Standoff Assembly Sequence
4.6. Wallmount Installation
(The following instructions apply to an installation on a concrete wall. For any other type of wall,
contact the manufacturer.)
Please refer to Figure 15 and to Figure 16.
1. Attach the alignment template to the wall.
2. Using the template as a guide, drill seven holes for concrete anchors. Insert seven concrete
anchors (McMaster-Carr catalogue number 92403A200, or equivalent). The middle holes
are designated for the mounting bracket. The other four holes are for the wallmount bracket.
3. Carefully and thoroughly fasten the anchors to the wall.