4.3. Configuration Restrictions
UPLINK DOWNLINK
Figure 13: PCS Frequency Allocation
The following configuration restrictions apply: (Please refer to Figure 13 above.)
• PCS operator operating on block A and the Paging operator must not reside on the same MRU.
• PCS operator operating on block B and the SMR operator must not reside on the same MRU.
•
PCS operator operating on block A and B and the SMR and Paging operators must not reside
on the same MRU.
• The PCS band is divided into six blocks. Blocks A, B, and C are 15 Mhz and blocks D, E, and F
are 5 Mhz. Only two adjacent blocks can be used on the same MRU. The adjacent blocks are:
A and D, B and E, and F and C.
4.4. Environmental Data
Maximum ambient operating temperature: 45° C
Maximum ambient temperature in a rack: 45° C
A
15
MHz
D
5
M
Hz
B
15
MHz
E
5
M
Hz
F
5
M
Hz
C
15
MHz
C
15
MHz
F
5
M
Hz
E
5
M
Hz
B
15
MHz
D
5
M
Hz
A
15
MHz
1850
1870
1890
1910
1930
1950
1970
1990