User Manual

Table Of Contents
Appendix
6.3 SNMP Management Using a Standard SNMP
Manager
The MA 860 packages provide MIBSs that enable standard SNMP (Version 2.0) managers such
as HP OpenView to view event traps sent by the MA 860 unit and to configure the unit.
NOTE: These traps provide a general indication of the type of failure. The MA MA 860 enables
identifying the source of the problem and system monitoring parameters. (Trap destinations and
community names were defined in section
5.2.1.3.
6.3.1 Traps List
NOTE: Traps are only sent to defined trap destinations
5.2.1.3.
The following traps are provided:
Table 6-2. List of MA 860 Traps
Name Type Severity OID Description
ma860powerUp NOTIFICATION-
TYPE
notification 81.4.2.0.1
System On.
ma860SerialNotify
NOTIFICATION-
TYPE
notification 81.4.2.0.2
serial communication
status failed success
ma860WceOverTemperature
NOTIFICATION-TYPE
major 81.4.2.0.3
WCE Temperature
over 60ξΆ‘ C
ma860WceNormalTemperature
NOTIFICATION-TYPE
info 81.4.2.0.4
WCE Temperature
Normal
ma860APaDisconnect
NOTIFICATION-TYPE
major 81.4.2.0.5
AP type 802.11 a
DisConnected
ma860APaDetected
NOTIFICATION-TYPE
info 81.4.2.0.6
AP type 802.11 a
Connected
ma860APbgDisconnect
NOTIFICATION-TYPE
major 81.4.2.0.7
AP type 802.11 bg
DisConnected
ma860APbgDetected
NOTIFICATION-TYPE
info 81.4.2.0.8
AP type 802.11 bg
Connected
ma860WceDisconnected
NOTIFICATION-TYPE
major 81.4.2.0.9
WCE Disconnected
ma860WceDetected
NOTIFICATION-TYPE
info 81.4.2.0.10
WCE detected by
MA860
MA-860 Installation and Configuration Guide 62