Power-up and Provisioning the Unit
5.6 Changing Password
To change the password of the User Name:
1. Click the Security tab in the Main window.
2. To change the password:
• In the Login Password field, enter the password to login to the current session.
• In the User Name field, select the User Name whose password is to be changed.
• In the New Password field, enter the new password.
• In the Verify Password field, type the new password again.
• Click Apply.
5.7 Web Access Adjustment
Note: The default gain for each channel is set to 0dB.
By default, the AGC is enabled, therefore the adjustment procedures are automatically
performed at power-up and no manual adjustment procedure is required.
The system periodically verifies that the AP RF signal level and the WCE output signal level are
within 2dB of each other. If it is out of range of the 2dB, the system automatically performs
adjustment (if the AGC is enabled).
The manual adjustment procedure can be used by MobileAccess service personnel to readjust
the system any time. The manual adjustment procedure can only be performed if AGC is
disabled (where AGC can be disabled by MobileAccess service personnel).
MA-860 Installation and Configuration Guide 46